What specifications define an ignition transformer for an oil burner system?

Pagina iniziale FAQ Transformer Oil Maintenance Transformer Oil What specifications define an ignition transformer for an oil burner system?

Stai visualizzando 2 post - dal 1 a 2 (di 2 totali)
  • Autore
    Post
  • #2364
    Alexandre
    Partecipante

    What specifications define an ignition transformer for an oil burner system?

    #2365
    Thomas
    Partecipante

    Specifications include primary voltage and frequency, secondary output voltage typically 8-12 kV, rated secondary current suitable for stable spark, duty cycle rating, insulation class, and environmental temperature rating. Mechanical specifications include mounting footprint, terminal style, and enclosure protection. Some applications require continuous duty while others are intermittent. Compatibility with the burner control system and safety approvals are important. A correctly specified ignition transformer delivers consistent spark energy without overheating or excessive electromagnetic noise.