  • 井上 零
    Participant

    Specifications define required dielectric and chemical performance limits and the test methods used. Typical parameters include breakdown voltage, moisture content, acidity, dielectric dissipation factor, resistivity, interfacial tension, viscosity, density, flash and fire points, pour point, oxidation stability, and sometimes inhibitor type and concentration. Some specs include corrosive sulfur requirements, gassing tendency, PCB limits, and compatibility expectations for materials. Procurement specs also define packaging, cleanliness requirements, sampling and acceptance procedures, and documentation such as certificates of analysis and SDS.

    井上 零
    Participant

    Oil type transformers use liquid insulation and cooling, enabling compact high voltage, high MVA designs with efficient heat transfer, but they require spill containment and fire risk mitigation. Dry type transformers use air and solid insulation (often cast resin), making them preferred indoors or where environmental constraints prohibit oil. Dry types typically have lower spill and fire hazards but may be larger or more expensive at high ratings. Grid selection depends on location, rating, safety rules, and lifecycle costs.

    井上 零
    Participant

    Start with safety: shut off power and fuel supply, verify lockout. Check primary power, fuse, and control signal to the ignition transformer. Inspect electrode condition, gap, cracks in porcelain, and grounding. Measure transformer secondary output with the correct HV tester or substitute a known good unit. Check wiring, ignition cable insulation, and burner motor sequence. If spark is weak, intermittent, or absent, confirm proper duty cycle and replace the transformer if output is low or unstable.

    井上 零
    Participant

    Shell Diala AX is used in power and distribution transformers requiring high oxidation stability and clean dielectric performance. It is suitable for utilities, industrial substations, and renewable energy installations. The oil supports long service intervals and stable diagnostic behavior under high load conditions.

    井上 零
    Participant

    Shell transformer oils are used in power transformers, distribution transformers, and industrial transformers where a compliant insulating fluid is required for dielectric and cooling performance. Typical applications include substations, industrial plants, renewable integration transformers, and utility distribution networks. Selection depends on standard compliance, inhibitor package, and local utility specifications. In practice, engineers choose based on performance data sheet, testing certificates, and compatibility with existing oil for topping up or retrofill, rather than on brand alone.

    井上 零
    Participant

    Approximately 7.3 lb per gallon, important for transport, lifting, containment, and storage calculations.

    井上 零
    Participant

    Frequency depends on criticality, loading, and condition history. Critical transmission transformers may be sampled quarterly or semiannually, while less critical distribution units may be annual or event based. After abnormal DGA, overheating, relay operations, or oil leaks, sampling is performed sooner and more frequently to trend changes. Online monitoring can reduce manual sampling frequency but still needs periodic validation. The main goal is trend quality, because consistent intervals and methods produce reliable condition based maintenance decisions.

    井上 零
    Participant

    In bulk procurement, oil rates are negotiated based on volume commitments, contract duration, specification stability, and delivery terms. Utilities often link pricing to published feedstock indices with adjustment clauses. Discounts apply for bulk tanker delivery versus drums. Contracts typically include quality guarantees, testing certificates, and penalties for non-compliance. Long-term agreements reduce price volatility and ensure consistent oil characteristics across transformer fleets.

    井上 零
    Participant

    Oil filled transformers offer superior cooling and insulation, enabling higher power density and easier scaling to high voltage and high MVA ratings. They are typically more cost effective for large outdoor substations and tolerate overloads better due to thermal mass. Disadvantages include fire risk, spill risk, and maintenance needs like oil testing and leak management. Dry type units reduce fire and environmental risks and suit indoor installations, but often have higher cost per kVA, larger size at high ratings, and different thermal limits.

    井上 零
    Participant

    Legacy transformer oils manufactured before the late 1970s may contain polychlorinated biphenyls (PCBs), which are toxic, persistent environmental pollutants. PCB exposure is linked to cancer, neurological damage, and immune system disorders. These oils pose serious risks during leaks, fires, or improper disposal. Because PCBs bioaccumulate and do not easily degrade, contaminated equipment and soil require specialized handling and remediation under strict environmental regulations.

    井上 零
    Participant

    In refineries and petrochemical plants, purification is used for turbine oils, lube oils, and hydraulic fluids exposed to heat, pressure, and contaminants. Fluidex industrial units clean these oils inline or offline, improving uptime in compressors, pumps, and reactors.

    in reply to: What is a lube oil purifier and where is it used? #1831
    井上 零
    Participant

    A lube oil purifier cleans turbine and compressor oils by removing water, varnish, and sludge. Used in power plants, paper mills, and heavy industry. Fluidex lube oil purifiers extend oil life and reduce maintenance frequency in rotating machinery.

    井上 零
    Participant

    Choose a system with: vacuum dehydration, sludge removal, acid neutralization (optional), and flow capacity matching your needs. Fluidex offers waste oil purifiers for transformer, turbine, and hydraulic oils. Units are available in mobile or fixed configurations.

    井上 零
    Participant

    For critical transformers, a dissolved gas analysis should be done every 6-12 months – or after any abnormal electrical event. Fluidex provides inline and portable sampling solutions that simplify regular testing routines. They also manufacture filtration systems with built-in DGA sampling ports, so you can monitor gas levels after oil purification. Early detection of hydrogen, acetylene, or ethylene can prevent costly failures.

    井上 零
    Participant

    Turbine oils require low water content and excellent cleanliness to avoid varnish and wear. Fluidex produces oil filtering machines capable of high flow rates, with vacuum dehydration and particulate filtration for turbine-grade lubricants. These machines are often used in power plants, cement factories, and paper mills, where unplanned shutdowns are extremely costly. Their equipment helps extend the life of expensive machinery and minimize downtime.

Viewing 15 posts - 31 through 45 (of 55 total)