Categories :

Fluidex Transformer Oil Tan Delta Tester

FLD T Oil Tan Delta Tester

The FLD T tester is designed for measuring the dielectric loss tangent (tan δ), permittivity, and electrical resistivity of transformer oils and other dielectric fluids in compliance with IEC 60247-2004-02 (VDE-0380-2:2005_01), ASTM D924-08, and ASTM D1169-02 standards. This fully automatic FLD T tan delta tester enables testing according to these standards, as well as custom procedures specified by the user in the setup menu.
  • Description

    The FLD T tester is designed for measuring the dielectric loss tangent (tan δ), permittivity, and electrical resistivity of transformer oils and other dielectric fluids in compliance with IEC 60247-2004-02 (VDE-0380-2:2005_01), ASTM D924-08, and ASTM D1169-02 standards.

    This fully automatic FLD T tan delta tester enables testing according to these standards, as well as custom procedures specified by the user in the setup menu.

  • Specification
    No.

    Parameter

    Value

    1 Operating AC voltage, V

    100–260

    2 Power frequency, Hz

    48–63

    3 Power requirement, VA

    Below 250

    4 Applied measuring АС voltage, kV

    Sinusoidal, 500–2,000 V actual

    5 Tan δ measurement range

    0.00001–4

    6 Tan δ measurement resolution

    1×10-6

    7 Tan δ measurement tolerance

    +/- 1% of measurement + 0.00008

    8 Dielectric constant (ε) measurement range

    1.0 – 15.0

    9 Dielectric constant (ε) measurement tolerance

    +/- 1%

    10 Electrical capacitance (C) measurement range, pF

    20–1,000

    11 Electrical capacitance (C) measurement tolerance, pF

    +/- 1% + 1

    12 Oil temperature measurement range, oF (ᴼС)

    68–230 (20–110)

    13 Measuring cell volume, in³ (cm³)

    2.6 (42)

    14 Electrical capacitance of empty cell, pF

    65–85

    15 One measurement duration, minutes

    60

    16 AC frequency setting range, Hz

    45–65

    17 Temperature measurement resolution, ᴼF (ᴼС)

    33 (0.5)

    18 Operating temperature, ᴼF ( ᴼС)

    68–230 (20–110)

    19 Storage temperature, ᴼF (ᴼС)

    From – 4 to +140 (from – 20 to +60)

    20 Relative humidity, %

    Up to 90, non-condensing

    21 Dimensions, in (mm)

    400/450/300 (16/18/12)

    22 Weight, lbs (kg)

    12 (5.3)

  • Advantages

    The Fluidex oil tan delta tester for measuring the dielectric loss tangent offers several significant advantages that make it particularly suitable for both industrial and research applications. Firstly, it ensures rapid measurement while maintaining a high degree of accuracy, which is essential for efficient and reliable data collection. The measurement process is fully automated and computer-controlled, allowing for the seamless saving and printing of results, thus facilitating streamlined documentation and analysis.

    Furthermore, the Fluidex tester features a high degree of setting variability, making it an excellent solution for research purposes where different experimental conditions may be required. Its lightweight and compact design enhance its portability and ease of use, enabling convenient operation in various environments.

  • Application

    FLD T testers can be used for measuring the tan delta of mineral transformer oils, silicone transformer oils, Midel 7131 transformer oils, FR3 dielectric fluids.

  • Video

  • Configarator
    Loading...


    * Required

Become a Fluidex dealer ?

Fill out the form and become our dealer!

      Fluidex

      Contact us!

        Fluidex

        Request price